How to Buy an Ultrasound Machine in Malaysia: From Exam List to First Scan
Buying an ultrasound machine is a short project, not a single order. The steps from first enquiry to the first patient scan, what to send so that quotations can be compared, the line items a written quotation should carry, the checks to make before you pay, and what to sign off at handover.
Six steps from enquiry to first scan
Whoever you buy from, a well-run purchase follows the same order. Each step leaves you with something to keep — a requirement, a scorecard, a quotation, a screenshot, a signed report — so the next step has a fixed reference and nothing is agreed only by word of mouth.
- Write down your exam list: the scans you do each week, who performs them and in which rooms.
- Turn it into a configuration: the format (cart, laptop or handheld), each probe and the software packages those exams need.
- See that configuration on your own exams at a demonstration, and score it.
- Get a written, itemised quotation for exactly that configuration.
- Check the MDA registration of the system and each probe, and the seller’s establishment licence, before you pay.
- Accept the unit at installation: acceptance checks, presets, applications training and a signed handover.
Read next How to run a fair ultrasound demoChoosing a machine by specialty
What to send when you ask for a quotation
The more of this you send in the first message, the fewer rounds of questions — and the closer two suppliers’ quotations will be to each other, which is what makes them comparable.
| Tell the supplier | Why it matters |
|---|---|
| Specialty and practice type | A GP clinic, O&G practice, emergency department and aesthetic clinic need different platforms and software. |
| Exam list and weekly volume | Abdomen, early pregnancy, fetal growth, thyroid, vascular, MSK or cardiac work each point to particular probes and measurement packages. |
| Who scans | Doctors new to ultrasound benefit from simpler presets and more applications training; specialists need deeper tools. |
| Room or portable | A dedicated scan room suits a cart; scanning between rooms, wards or on home visits suits a laptop or handheld system. |
| Probes you already own | Probes are platform-specific and rarely transfer to another system, so say what you have. |
| Image storage and reporting | A printer, USB export, DICOM to a PACS or reports into a clinic system each change what must be quoted. |
| City and target date | Lead time, who installs and trains, and engineer coverage all depend on where the machine will be used. |
What the written quotation must list
A one-line quotation such as “ultrasound machine with three probes” can be neither compared nor enforced. Ask for each of these as its own line, with model names and, where possible, part numbers.
- The system: brand, exact model, platform or software version, and the cart, laptop or handheld format.
- Each probe by name and type, as a separate line. After the system itself, probes are usually the largest part of the cost.
- Software packages and licences switched on — for example obstetric calculations, cardiac, vascular, elastography or needle guidance — and whether any are time-limited or subscription-based.
- Accessories: cart or stand, printer, UPS, footswitch, gel warmer, biopsy or needle guides.
- Delivery and installation, and who carries them out.
- Applications training: how many sessions, for how many users and which exams.
- Warranty for the system and, separately, for each probe, including what is excluded — drops, cut cables and cracked lenses are common exclusions.
- Service after the warranty: preventive maintenance visits, response time to your address, and a loaner probe or system during repairs.
- DICOM, worklist or PACS connection if you need it, and who configures it.
- Lead time from order to installation, payment terms and how long the quotation is valid. Imported systems are priced against the exchange rate.
- The MDA registration number for the system and every probe.
- At AA Alive, the written quotation states who delivers, installs, trains and services the system, and what each of those costs.
Read next What drives the price of an ultrasound machineReading a spec sheet and writing your ownWhat a service contract should cover
New, refurbished or rented
Decide this before asking for quotations, so that every supplier quotes the same kind of machine.
New
The current platform, the full manufacturer warranty, the longest parts and software support, and an upgrade path. The usual choice for a machine that will be used every day for years.
Brands you will see in MalaysiaRefurbished
A proven platform for less, but check each probe, whether the software licences transfer to you, when the maker stops supplying parts, and MDA registration.
Checks before buying refurbishedRental or lease
Useful for a trial service, a locum period or a short project. Compare the total paid over the period with the cost of buying.
Rent, lease or buyWho can buy and use an ultrasound machine
Malaysian rules apply to the device, to the company that sells it and to the person scanning, in different ways. Ultrasound does not use ionising radiation, so the Atomic Energy Licensing Act 1984 does not apply to it the way it does to X-ray.
The device
Under the Medical Device Act 2012 (Act 737), the system and its probes must be registered with the Medical Device Authority (MDA) before they are placed on the Malaysian market — new, refurbished or rented.
The seller
Section 15 of Act 737 requires the manufacturer, importer, distributor or authorised representative placing a registered device on the market to hold an MDA establishment licence. Retailers fall outside that definition, but the company that brought the device in must hold one.
The clinic
A private clinic that scans patients must itself be registered or licensed under the Private Healthcare Facilities and Services Act 1998 (Act 586).
The person scanning
In October 2025 the Malaysian Medical Association, the Obstetrical and Gynaecological Society of Malaysia and the College of Radiology warned about unlicensed ultrasound centres run by unregulated sonographers. They said GPs with appropriate point-of-care training may do basic, focused scans, while detailed fetal anomaly, fertility and lesion-characterisation scans belong with specialists.
Read next POCUS training in MalaysiaA first ultrasound for a GP clinic
Before you pay: registration and seller checks
- Search each MDA registration number on the quotation in the Malaysia Medical Device Register (mdar.mda.gov.my), and check that the brand, model and probe names match.
- Search the seller, or the importer it names, under Licensed Establishment on the same register.
- If you are offered the demonstration unit, confirm in writing that it is a registered unit. A device imported under MDA’s demonstration exemption may not be placed on the market.
- Agree in writing what is paid on order and what is paid after installation and acceptance.
- Save dated screenshots of the register records with the quotation and invoice.
Read next How to check MDA registrationHow to choose a supplier
Installation and handover: what to sign off
WHO’s procurement guide for medical devices treats commissioning — checking the documents, function, safety and acceptance tests, user training and handover — as part of the purchase, not an extra. For an ultrasound machine that means:
- Every item on the quotation delivered, with the serial numbers of the system and each probe on the installation report.
- Each probe imaged on a phantom or volunteer and checked for dropout lines, and each lens and cable inspected.
- The software options on the quotation shown as active on the system.
- Presets set up for your exams; date, time and clinic name entered; export to USB, printer or PACS tested.
- Applications training delivered and recorded: who attended and which exams were covered.
- The warranty start date, the service contact and the agreed response time given to you in writing.
Related guides
Ultrasound Machine supply near you
Written quotes for clinics across Malaysia, handled from Batu Caves, Kota Kinabalu and Kuching.
Sources and further reading
- Medical Device Authority — Establishment licence information (section 15, Act 737)
- Medical Device Authority — Malaysia Medical Device Register, public search
- MDA/GD/0018 — Import and/or supply of unregistered medical devices for demonstration for marketing or education (2018)
- WHO — Procurement process resource guide (Medical device technical series, 2011)
- Malaysian Medical Association — Medical groups warn of safety risks posed by unlicensed ultrasound centres (NST, 13 Oct 2025)
Frequently asked questions
Where can I buy an ultrasound machine in Malaysia?
Can I buy my own ultrasound machine?
Do I need a licence to buy an ultrasound machine in Malaysia?
What should an ultrasound machine quotation include?
How long does it take to get an ultrasound machine after ordering?
Can I buy the demonstration unit?
Get a written quotation
Tell us your clinic or lab type, daily workload and location. We match suitable models and send a written quotation that states who handles delivery, installation and training, and what each costs.
010-905 2891 · Mon–Sat, 9:00 am – 6:00 pm