Ultrasound in Dengue: Finding Plasma Leakage Before It Shows
Malaysia passed 76,000 dengue cases by mid-October 2026. Plasma leakage is what makes dengue dangerous, and ultrasound can often show the fluid before the bedside examination does. What to look for, what the Malaysian guideline says, and what a scan cannot tell you.
Dengue in Malaysia in 2026
The national iDengue dashboard showed 76,167 dengue cases from 4 January to 14 October 2026, and 68 deaths up to 11 October. By epidemiological week 35 the Health Ministry had already reported 65,979 cases, against 39,616 in the same weeks of 2025. The ministry and dengue advocates have linked the rise to DENV-3 replacing DENV-2 as the dominant serotype — a strain many Malaysians have not met before. Selangor has the most cases, followed by the Federal Territories and Johor. With the year-end monsoon rains still to come, clinics and emergency departments should plan for busy months.
Read next Serial FBC and haematocrit in dengue (hematologyanalyser.my)Baca dalam Bahasa Malaysia
Why plasma leakage is the thing to find
In the critical phase — often after the third day of fever, around the time the temperature falls — fluid leaks out of the capillaries into the chest, the abdomen and the tissues. The Malaysian Clinical Practice Guidelines on dengue in adults list a raised haematocrit, haemodynamic instability, fluid in the extravascular space and low protein as evidence of leakage, and count third-space fluid — ascites, pleural and pericardial effusion — among the warning signs. Small collections are hard to find by examination. Ultrasound can show them early, and repeat scans show whether they are growing.
What the scan looks for
| Finding | Where to look | What it suggests |
|---|---|---|
| Gallbladder wall thickening | Right upper quadrant, measuring the anterior wall | Most studies call a wall above 3 mm thickened. Often the earliest sign: a 2026 review notes it can appear one to three days before ascites or effusion |
| Pleural effusion | The costophrenic angles on both sides, scanning from the flank | Fluid in the chest |
| Ascites | Morison’s pouch between the liver and right kidney, around the spleen and in the pelvis | Free fluid collects first in these dependent spaces |
| Pericardial effusion | Subcostal or parasternal view of the heart | Fluid around the heart, usually with more severe leakage |
| Inferior vena cava (IVC) | Subcostal long-axis view, just below where it joins the right atrium | Its size and how much it collapses with breathing — an indirect guide to intravascular volume, read with the clinical picture |
| B-lines | Anterior and lateral chest wall | Fluid in the lung interstitium, which may also follow generous IV fluid |
Read next Lung signs: B-lines and effusions
What the Malaysian guideline says
The CPG Management of Dengue Infection in Adults (third edition, 2015, published by MaHTAS) states that chest X-ray and ultrasound, where available, are required for patients suspected of vascular leakage, but must not delay admission. It says ultrasonography may be performed by trained personnel to look for third-space fluid — pleural effusion, pericardial effusion, gallbladder wall oedema and intraperitoneal fluid — and for collapsibility of the IVC as an indirect indicator of the intravascular fluid compartment and the response to IV fluids.
- Ultrasound is an adjunct. Monitoring still rests on serial FBC and haematocrit, vital signs, urine output and the warning signs.
- The CPG advises primary care providers without immediate haematocrit testing to refer patients to the nearest health facility — with or without an ultrasound machine.
- A normal scan early in the illness does not rule out leakage later. Findings change day by day through the critical phase, so repeat the scan.
- There is no validated dengue-specific POCUS protocol yet. A 2026 review in the World Journal of Critical Care Medicine proposed a structured one, which shows how unsettled practice still is.
Read next POCUS equipment and governance
How useful is gallbladder wall thickening?
It is the most-studied single sign. At Hospital Sungai Buloh, Ibrahim and colleagues (The Ultrasound Journal, 2022) scanned 44 adults with dengue in the emergency department using a 3 mm cut-off. Gallbladder wall thickening had 90.5% sensitivity and 69.6% specificity for severe dengue, compared with dengue with warning signs. A 2025 meta-analysis of 19 studies found a pooled sensitivity of 88% and specificity of 63%. In practice, a normal wall makes severe disease less likely, and a thick wall is a prompt to look harder — not a diagnosis on its own. A recent meal, hepatitis, heart failure and low albumin also thicken the wall.
Probes and machine features for a dengue scan
Convex probe
Covers the gallbladder, Morison’s pouch, the spleen, the pelvis and the pleural bases. It is the one probe a dengue scan cannot do without.
Phased-array probe
Optional, for the pericardium and the IVC between the ribs. The convex probe can usually see both through the subcostal window.
Linear probe
Shows the pleural line in fine detail and helps in small children, but is not essential for adults.
Portable or handheld
Many dengue scans happen in a crowded ward or observation area. A portable or handheld system with abdomen and lung presets and a quick start-up suits that work; check depth on larger adults before buying.
Handheld scanners comparedMeasurement and storage
Calipers for wall thickness and IVC diameter, M-mode for IVC collapse, and clips saved under the patient’s name so the next scan can be compared with this one.
Read next Portable ultrasound machinesCleaning probes between patients
Related guides
Ultrasound Machine supply near you
Delivery, installation and training across Malaysia from Batu Caves, Kota Kinabalu and Kuching.
Frequently asked questions
Can ultrasound diagnose dengue?
What is gallbladder wall thickening in dengue?
Does a GP clinic need ultrasound to manage dengue?
Which probe is used to look for plasma leakage?