Ultrasound Machine Glossary

45 terms you will meet in ultrasound machine quotations, brochures and spec sheets — defined in plain English.

45 terms, A to Z

Last updated:

A–Z of terms

3D / 4D
Volume imaging (4D = live 3D), mainly used in obstetrics. Full guide
Acoustic shadowing
A dark band behind a structure that blocks most of the sound, such as a gallstone, kidney stone or bone. Full guide
ACR TI-RADS
The American College of Radiology’s scoring system for thyroid nodules: points for five ultrasound features set a level from TR1 to TR5 and the size at which FNA is advised. Full guide
ALARA
As low as reasonably achievable — the principle of scanning only as long and as intensely as needed. Full guide
Aliasing
Colour Doppler wrapping from red to blue when flow is faster than the scale setting can show. Full guide
Anisotropy
Tendons, ligaments and nerves looking bright only when the beam meets them at a right angle; tilting the probe makes a normal tendon look dark. Full guide
Antral follicle count (AFC)
The number of 2–10 mm follicles in both ovaries early in the cycle, used with AMH to estimate ovarian reserve. Full guide
B-lines
Bright vertical artefacts from the pleural line to the bottom of the screen; three or more between two ribs suggest fluid or thickening in the lung interstitium. Full guide
B-mode
The standard 2D grey-scale ultrasound image. Full guide
BI-RADS
The Breast Imaging Reporting and Data System — standard terms and assessment categories for breast imaging reports. Full guide
Colour Doppler
Shows the direction and speed of blood flow as colour over the image. Full guide
Compression ultrasound
Pressing on a vein with the probe: a vein that collapses completely is unlikely to hold a clot at that point — the basis of DVT scanning. Full guide
Convex probe
Curved low-frequency probe for abdomen and obstetrics. Full guide
Delamination
The bonded layers of a probe face lifting apart and trapping air, causing patchy loss of image; often repairable if caught early. Full guide
DICOM
The standard format for storing and sending medical images. Full guide
eFAST
Extended FAST: the FAST views plus both sides of the chest, looking for pneumothorax and blood in the chest. Full guide
Elastography
Measures tissue stiffness, used for liver, breast and thyroid on higher-end systems. Full guide
Element dropout
Failed crystal elements in a probe, seen as dark vertical bands in the image — usually after a drop. Full guide
Endocavity probe
Long narrow probe for transvaginal or transrectal scanning. Full guide
FAST
Focused assessment with sonography in trauma — checks for free fluid. Full guide
Gain
The overall brightness of the echoes on screen; too much fills fluid with grey noise. Full guide
High-level disinfection
The reprocessing standard for probes that touch mucous membranes, such as endocavity probes. Full guide
In-plane approach
Needling along the long axis of the probe so the whole needle shaft and tip stay visible. Full guide
Linear probe
Flat high-frequency probe for vessels, small parts, MSK and procedures. Full guide
Lung sliding
The shimmer of the pleural line with each breath; its absence raises the question of pneumothorax. Full guide
M-mode
A motion trace along one line over time, used mainly in cardiac imaging. Full guide
MDA registration number
The number the Medical Device Authority gives a registered device; search it on the Malaysia Medical Device Register before you buy. Full guide
Mechanical index (MI)
On-screen estimate of non-thermal effects such as cavitation; it matters most with contrast agents and in neonatal lung. Full guide
Modality worklist
A DICOM service that lets the scanner download booked patients from the clinic system, so names and IDs are not retyped. Full guide
PACS
Picture archiving and communication system — where DICOM images are stored and viewed. Full guide
Phased array probe
Small-footprint low-frequency probe for imaging the heart between the ribs. Full guide
Plasma leakage
Fluid escaping from the capillaries into the chest, abdomen and tissues in the critical phase of dengue; ultrasound can show it as effusions, ascites or a thickened gallbladder wall. Full guide
POCUS
Point-of-care ultrasound — focused bedside scans by the treating clinician. Full guide
POCUS logbook
A record of supervised scans with findings and final outcomes, used to show competence before a clinician is credentialed for an application. Full guide
Post-void residual (PVR)
The urine left in the bladder straight after the patient passes urine, often measured with a bladder scanner. Full guide
Preset
Saved machine settings for a particular exam, such as abdomen or thyroid. Full guide
Probe cover
A sterile or clean sheath used over endocavity probes and for procedures. Full guide
PW / CW Doppler
Pulsed-wave and continuous-wave spectral Doppler for measuring flow velocities; CW is needed for high cardiac velocities. Full guide
Shear wave elastography
Elastography that measures the speed of shear waves through tissue and reports stiffness in m/s or kPa. Full guide
TGC (time gain compensation)
Sliders that adjust brightness at each depth to make up for sound weakening as it travels into the body. Full guide
Therapeutic ultrasound
Physiotherapy units that deliver ultrasound energy to tissue, usually at 1 or 3 MHz, and make no image. Full guide
Thermal index (TI)
On-screen estimate of tissue heating — shown as TIS (soft tissue), TIB (bone at the focus) or TIC (bone at the surface); watch it especially with Doppler in pregnancy. Full guide
Tissue harmonic imaging
Builds the image from harmonic echoes generated in tissue, reducing haze and clutter. Full guide
Transducer (probe)
The handheld part that sends sound into the body and receives the echoes. Full guide
Ultrasound-on-chip
A probe built on a semiconductor chip instead of a piezoelectric crystal array, as in the Butterfly iQ. Full guide