Ultrasound Machine Specifications: Reading a Spec Sheet and Writing Your Own

A spec sheet describes the best a platform can do; the quotation describes what you will actually get. What each line on an ultrasound specification means, the documents to ask for, and a sample specification you can adapt for a quotation request or a tender.

Also called Ultrasound machine specifications, Ultrasound spec sheet, Ultrasound tender specification

Published:

Read the spec sheet in the right order

  • Start from your exam list, not the brochure. Every line you need should trace back to an exam you do.
  • Treat “up to”, “supports” and “available” as options until the quotation lists them. A brochure covers the whole platform family.
  • Find the probe list for the configuration you are being quoted, not the full catalogue of compatible probes.
  • Separate standard features from licensed options. Software such as 3D/4D, elastography, contrast imaging or advanced cardiac packages is usually sold as a licence for one system.
  • Ask whether any option is a time-limited trial or a subscription.

What each line means

Spec lineWhat it tells youWhat to ask
FormatCart, laptop/portable or handheldDoes it suit the rooms, the travel and the exams?
Monitor and touchscreenScreen size, resolution and mountingIs the arm adjustable, and is the screen readable from where the doctor sits?
Active probe portsHow many probes can stay connected at onceEnough for your daily probes without swapping? A separate pencil (CW) port?
Probe listEach probe’s type, model and frequency range in MHzWhich probes are in the quoted price, and which are extra?
Imaging modesB-mode, M-mode, colour, power, pulsed-wave and continuous-wave Doppler, tissue harmonics, compoundingWhich modes are standard and which need a licence?
Options and licences3D/4D, elastography, contrast, needle enhancement, automated measurementsIs each option licensed permanently to this system?
Measurement and report packagesObstetric, gynaecology, vascular, cardiac, urology and small-parts calculationsDo the tables and reports match how your doctors work?
Storage and exportInternal disk, USB, network and DICOM servicesWhich DICOM services are included, and is there a conformance statement?
BatteryScanning time on battery, charging time, hot-swapMeasured in scanning minutes, with which probe and mode?
Boot time and weightSeconds from power-on to scanning; kilograms with and without the cartMeasured at the demo, not only on paper
Safety and acoustic outputConformity with IEC 60601-1 and IEC 60601-2-37; MI and TI shown on screenTest reports or certificates, and acoustic output tables in the manual
Warranty and supportSystem and probe warranty; parts and software support periodStated separately for the system and each probe, in writing

Documents to ask for with the quotation

  • The MDA registration number for the system and for each probe, checked on the public register.
  • The company’s MDA establishment licence. MDA Circular Letter No. 1/2026, in force since 28 January 2026, asks healthcare facilities buying by tender to obtain three documents from the supplier: the establishment licence, the device registration certificate and a distributor appointment letter. Ask for the same three when you buy by quotation.
  • Evidence of conformity with IEC 60601-1 (general electrical safety and essential performance), IEC 60601-1-2 (electromagnetic compatibility) and IEC 60601-2-37 (the particular standard for diagnostic ultrasound equipment). IEC 60601-2-37 was revised in 2024, so ask which edition the system was tested to.
  • The DICOM conformance statement for the software version you will receive. Part 2 of the DICOM standard sets out what a conformance statement must contain.
  • The probe cleaning and disinfection compatibility list for every quoted probe.
  • The user manual, including the acoustic output tables, and the planned service schedule.

A sample specification you can adapt

An example for a general GP or O&G clinic system. Change the probes, modes and packages to match your exam list, and ask each supplier to answer every line with “complies”, “does not comply” or “option”, plus the detail.

Sample ultrasound specification — adapt the requirement column to your own exams
ItemRequirement (example)Supplier’s answer
FormatCart-based system with at least 3 active probe ports
MonitorFlat-panel monitor on an adjustable arm, plus a touchscreen or equivalent control panel
Convex probeAbdominal and obstetric use; frequency range covering about 2–5 MHz
Endocavity probeTransvaginal use; frequency range covering about 4–9 MHz; biopsy guide available
Linear probeSmall parts and vascular use; frequency range covering about 5–12 MHz or wider
Imaging modesB, M, colour, power and pulsed-wave Doppler; tissue harmonic imaging
PackagesObstetric, gynaecology and vascular measurements, with printable reports
DICOMStorage, modality worklist and obstetric structured report; conformance statement attached
ExportUSB export of images and clips; network connection
SafetyEvidence of conformity with IEC 60601-1, IEC 60601-1-2 and IEC 60601-2-37
RegistrationMDA registration number for the system and each probe
WarrantySystem and probe warranty periods stated separately
TrainingApplications training: number of sessions, number of users, follow-up visit
ServiceResponse time, preventive maintenance visits per year, loaner policy

Writing a fair tender or quotation request

  • Describe functions and ranges, not one model’s brochure numbers. A specification copied from one brand excludes the others and invites complaints.
  • Mark each line as mandatory or desirable, and keep the mandatory list short.
  • Ask for a line-by-line compliance statement, with page references to the brochure or manual.
  • Include a demonstration on your own exams, scored on a written scorecard, before the award.
  • Ask for the system, each probe, each software option, training, installation and service as separate priced lines.
  • State the documents you need at submission — registration, licence, appointment letter, conformity evidence — so incomplete bids are easy to set aside.

Frequently asked questions

What should an ultrasound machine specification include?
The format, monitor, number of active probe ports, each probe with its frequency range, imaging modes, licensed options, measurement and report packages, storage and DICOM services, safety standards, MDA registration, warranty, training and service terms.
What does “up to” mean on an ultrasound spec sheet?
It usually describes what the platform can do with every option fitted. Treat it as an option until the quotation lists it for your configuration.
Which safety standards apply to an ultrasound machine?
IEC 60601-1 for general electrical safety and essential performance, IEC 60601-1-2 for electromagnetic compatibility and IEC 60601-2-37 for diagnostic ultrasound equipment, including how acoustic output is reported.
What is a DICOM conformance statement?
A document from the maker listing which DICOM services the system supports and how. Ask for the one that matches the software version you will receive.
How do I write an ultrasound tender spec without favouring one brand?
Specify functions and ranges rather than one model’s figures, keep the mandatory list short, ask for a line-by-line compliance statement and include a scored demonstration on your own exams.
Do ultrasound probes need their own MDA registration?
Each probe must be covered by an MDA registration, which may be the system’s or the probe’s own. Ask for the number for every quoted probe and check it on the public register.

Get a written quotation

Tell us your clinic or lab type, daily workload and location. We match suitable models and send a written quotation that states who handles delivery, installation and training, and what each costs.

010-905 2891 · Mon–Sat, 9:00 am – 6:00 pm